1.4 FLOOR PROTECTOR
If the stove is to be installed on top of a combustible floor, it must be guarded by a non-combustible
material extending at least 18” (458mm) from the front and 8” (200mm) from the sides and the back
of the firebox., as shown in Figure 1.4 below.
Please refer to local building codes for suitable floor protection materials.
FRONT
18” (458 mm)
Canada
16" (406mm)
USA
SIDES
8” (200 mm)
Canada
8" (200mm)
USA
BACK
8” (200 mm)
Canada
8" (200mm)
USA
FIGURE 1.4 Floor protector
Caution: do not install in a bedroom.