READ AND KEEP THIS MANUAL FOR REFERENCE
45003A
Printed in Canada 16-09-2014
OWNER`S MANUAL
Solution 1.8-I and Solution 2.3-I Inserts
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD INSERT
Verified and tested following
ULC S628 and UL 1482 Standards
by:
Manufactured by : STOVE BUILDER INTERNATIONAL INC.
250, rue de Copenhague, Saint-Augustin-de-
Desmaures (Quebec) G3A 2H3
Tel.: 418 878-3040
Fax: 418 878-3001
www.enerzone-intl.com
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time
to time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - OWNER`S MANUAL

READ AND KEEP THIS MANUAL FOR REFERENCE 45003A Printed in Canada

Page 2 - INTRODUCTION

10 2.2 Installation instructions Inspect the masonry fireplace according to the safety information and fireplace requirements and have it cleaned and

Page 3

11 2.4 The masonry fireplace's draft control system If the fireplace's draft control system is to remain in the masonry fireplace, it must

Page 4

12 2.6 Positioning the unit In addition to ensuring compliance of the masonry fireplace hearth extension (see Compliance of the masonry fireplace in

Page 5 - Solution 1.8-I Dimensions

13 If a non-combustible material floor protection needs to be added in front and level with the hearth extension masonry fireplace (see Figure 2.6a),

Page 6 - Solution 2.3-I Dimensions

14 The use of an R value is convenient when more than one material is going to be used in the hearth extension to cover the combustible surface. This

Page 7

15 The more extended the insert, the greater the heat transfer to the room. When installed as an extended insert, the front edge of the air jacket wi

Page 8

16 Thermal characteristics of common floor protection materials* MATERIAL CONDUCTIVITY (k) PER INCH RESISTANCE (R) PER INCH THICKNESS Micore® 160 0.

Page 9 - Section 2.0 Installation

17 MINIMUM MASONRY OPENING Solution 1.8-I Solution 2.3-I J 21 1/4” (540 mm) 23 3/8” (594 mm) K 28 7/8” (733 mm) 28 7/8” (733 mm) L 13 1/8” (

Page 10

18 2.8 Connector installation A masonry flue connector may provide acceptable performance (Figure 2.8a); however, we recommend the use of a chimney l

Page 11 - SHELF POSITIONING FOR

19 2.8.1 Chimney liner installation To install of the chimney liner, the preferred methods are those found in Section 2.8.1.1. Use a liner offset ada

Page 12

2 INTRODUCTION SBI INC., one of the most im portant wood stove and fireplac e manufacturers in Canada, congratulates you on your purchase and wishes t

Page 13

20 2.8.1.2 If the chimney liner does not align with the insert’s flue outlet: You can get a liner offset adapter (AC01370), sold separately. If you m

Page 14

21 2.9 Air control plate, faceplate and fan Assembly Instructions 1. Place the faceplate panels with the finished side down on a flat, soft, non-ab

Page 15

22 2.10 Adapter for fresh air kit installation instructions 1- Open the rectangular outlet on the side of the unit by gently removing the materia

Page 16

23 Section 3.0 Operation 3.1 Safety Information 1. This insert is designed for safe operation WHEN BURNING CORDWOOD ONLY. Altering or modifying t

Page 17

24 air leakage into the unit, such as through deteriorated gaskets or cracked or broken glass. Do not operate the insert without a door gasket. Leak

Page 18

25 5. Decayed wood or low density wood has very little energy content or heating value, and will not burn satisfactorily for long periods of time. A

Page 19 - 1.2) only as a last resort

26 4. Set the draft control at high,(see Table3.4) 5. Light a fire at the bottom of the crumpled paper and close the door. If the fire tends to go

Page 20

27 3.5 Maintaining The Fire Your Enerzone insert will work best if a thick bed of hot embers is maintained in the bottom of the firebox, and a minimu

Page 21

28 Section 4.0 Maintenance 4.1 Care And Cleaning Clean the insert frequently so that soot, ash and creosote do not accumulate. Do not attempt to cl

Page 22

29 4.2 Ash Removal CAUTION: Ashes can start fires, even after several days of inactivity. Never dispose of ashes in a combustible container. Remov

Page 23 - Section 3.0 Operation

3 TABLE OF CONTENTS INTRODUCTION ... 2Section 1.0 Pre-Installation Require

Page 24

30 All firebrick and duraboard baffles must be properly in place for correct burning operation. Have any damaged firebricks replaced. Check the fireb

Page 25

31 Figure 4.4.2b – Firebrick layout for 1.8-I model ITEM PIECE # DESCRIPTION QTY1 29001 4" X 8" X 1 1/4'' REFRACTORY BRIC

Page 26 - DAMPER OPERATION

32 4.5 Secondary Air Tube Replacement (see Figure 4.5) 1. Remove cotter pin at RH end of tube. 2. Slide tube to left and lower tube end below RH p

Page 27

33 4.6 Fan Maintenance & Care Clean the fan air inlet louvres and squirrel cage impeller regularly. The fan should be kept clean and dust free.

Page 28 - Section 4.0 Maintenance

34 Section 5.0 Specifications 5.1 Solution 1.8-I Insert Model Fuel Type Cordwood Test Standards ULC S628 (CSA B366.2) & UL 1482 reside

Page 29

35 5.2 Solution 2.3-I Insert Model Fuel Type Cordwood Test Standards ULC S628 (CSA B366.2) & UL 1482 residential. Maximum recommen

Page 30

36 ENERZONE LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This

Page 31

4 Section 4.0 Maintenance ... 284.1 Care And Cleaning ...

Page 32

5 Solution 1.8-I Dimensions

Page 33 - "ALTERING

6 Solution 2.3-I Dimensions

Page 34 - Section 5.0 Specifications

7 Section 1.0 Pre-Installation Requirements 1.1 Masonry & Zero Clearance Requirements The masonry fireplace must meet the minimum code requiremen

Page 35

8 1.2 Venting Requirements The flue is a critical component to a satisfactory installation. Your insert will attain its best performance if installe

Page 36

9 Section 2.0 Installation 2.1 Safety information NOTE: THIS APPLIANCE IS NOT RECOMMENDED FOR USE IN A HOME IF AN OCCUPANT HAS ANY RESPIRATORY OR A